PULLEY LOAD CELL
Features: Compact, excellent resolution. Easy to assemble, high resonant frequency. Protection against overloads.
Applications:coil winding machines, winding machines, unwinding machines, wire tensioner for any applications that have to measure the tension of wires, tapes, optical fibres, tessil wires, etc.
Click to enlarge image
Material | Aluminium/Steel |
Nominal load | 25, 50, 125, 250, 500, 1000 N |
Limit load | 300 % F.S. |
Breaking load | 500 % F.S. |
Supply voltage | Maximum 18 V dc |
Sensitivity | 1 mV/V |
Output tollerance | 0,2 % F.S. |
Zero tollerance | 1 % F.S. |
Linearity | 0,2 % F.S. |
Hysteresis | 0,2 % F.S. |
Reapeatability | 0,2 % F.S. |
Input resistance | 350-360 ohm |
Output resistance | 350-353 ohm |
Insulation resistance | >= 2000 Mohm |
Creep (30 Minutes) | 0,03 % F.S. |
Thermal compensation | -10 / +40°C (14 / +104°F) |
Operating temperature | -20 / +70°C (-4 / +158°F) |
Temperature deviation zero | 0,003 % F.S. / °C |
Temperature deviation full scale | 0,002 % F.S. / °C |
Protection class | IP 54 |
Connection | Panel male connector UTS08E4P |
Standard cable length | Loose female connector UTS6JC8E4S, connection cable 4 x 0,25 (length to be defined) |
Type | CONNECTOR MIL 4P IT3106A-14S |
Length | 3 m (body lead cell not connected shield) |
Pin A | - IN |
Pin B | - OUT |
Pin C | + OUT |
Pin D | + IN |
General precautions to be followed in the installation and assembly of load cells: